Description
Product Features
- Large dynamic range
- Low event dead zone and attenuation dead zone
- High testing accuracy
- Millisecond-level real-time test refresh rate
- Fast data transfer via Ethernet interface
- Automatic monitoring of communication optical signals
- Supports SNMP-based unified network management platform, management methods include CLI (telnet and console), Web, NetRiver (graphical interface)
Product Parameters
System Parameters | Technical Specifications | ||
---|---|---|---|
Dynamic Range (SNR=1) at 25℃ | 24-35 dB (typical, pulse width: 20 μs) | ||
Dynamic Range (SNR=1) at -5℃ to 55℃ | 22-33 dB (typical, pulse width: 20 μs) | ||
Wavelength | 1310 ±20 nm | 1550±20 nm | 1625±10 nm |
Test Fiber | 10 μm/125 μm single-mode fiber (ITU-T G.652) | ||
Pulse | 3, 5, 10, 30, 50, 100, 275, 500, 1000, 5000, 10000, 20000 ns | ||
Test Range | 0.5, 2.5, 5, 15, 40, 80, 120, 160, 200 km | ||
Event Dead Zone | ≤3 m | ||
Attenuation Dead Zone | ≤15 m | ||
Sampling Interval | 0.125 to 2 m | ||
Sampling Points | 128,000 | ||
Reflection Setting Range | 1.30000 to 1.80000 | ||
Testing Distance Uncertainty | ±(1+0.005%×distance+sampling resolution) | ||
Linearity | ±0.05 dB/dB | ||
Return Loss Test Accuracy | ±2 dB | ||
Automatic Test | Test Items: Total loss, distance for each event point, link loss, return loss or reflection Thresholds: Link loss: 0.01 to 9.99 dB Reflection: -14 to -70 dB; End: 1 to 99 dB Number of Event Points Detected: Up to 99 Auto Configuration: Distance range, pulse, averaging count |
||
Manual Test | Test Items: Transmission distance, 2-point method, link loss, reflection | ||
Laser Safety | IEC 60825-1:2007: CLASS 1 21 CFR 1040.10 |
||
Power Supply | +12±1V, maximum 1.5A | ||
Interfaces | Ethernet Interface: 20-pin to 10/100M RJ45 interface Serial Port: RS-232C: 115.2 kbps (set IP address via RS-232C interface) |
||
Size and Weight | 148.4×85.4×22 mm, less than 0.5 kg | ||
Environmental Conditions | Operating Temperature: -5℃ to +55℃ Operating Humidity: ≤95% (non-condensing) Storage Temperature: -40℃ to +70℃ |
||
EMC | EN61326-1, EN61000-3-2 |